The Output Post-processor is running but has not picked up this request
ERROR
OPP Error in the Log file:
————————————————————————
The Output Post-processor is running but has not picked up this request.
No further attempts will be made to post-process this request, and the request will be marked
with Warning status.
Setting the profile option Concurrent: OPP Response Timeout to a higher value may be necessary.
————————————————————————
SOLUTION
Solution 1. Restart the Output Post Processor and re-test the issue
Solution 2. If the above didn’t solve your issue, Increase the below profile options and re-test the issue
Concurrent:OPP Process Timeout to 600 (300*2)
Concurrent:OPP Response Timeout TO 240 (120*2)
Solution 3. Increase the processes of the Outpost Processor
Navigation: Concurrent > Manager > Define
then restart the OPP